Purpose #
This article demonstrates how to use CET.Calculators to design a four-bolted unstiffened extended moment end plate connection. This is form AISC AISC Design Guide 4, Extended End-Plate Moment Connections Seismic and Wind Applications, Example 4EB.
Limitations #
- Don’t support beam flange stiffener
- Only allow 4 bolt pattern
Data Input #
The fastest way to input data is to select “Moment End Plate” from “Examples” selection and then choose “Design Guide 4, 4EB”. Then users can change any inputs.
Compare results with AISC Design Guide 4 Example 4EB #
Item | Step in Design Guide 4 | Connection Calculator Results | AISC Design Guide 4, Example 4EB Results | Differences |
Required Bolt Diameter | Step 3 | 0.9645″ | 0.96 “ | 0.5% |
No Prying Bolt Moment | Step 4 | 4300 k-in | 4301 k-in | 0 |
0Required End Plate Thickness | Step 5 | 0.846″ | 0.85″ | 0.5% |
Shear Yielding of Extended Portion of End Plate | Step 8 | 212.6 kips | 213 kips | 0.2% |
Shear Rupture of Extended Portion of End Plate | Step 9 | 172.8 kips | 179 kips | 3.5% (1) |
Bolts Shear Rupture | Step 11 | 113.1 kips | 113 kips | 0 |
Compression Bolt Bearing | Step 12 | 316.7 kips | 411 kips | 23 % (2) |
Beam Flange to End Plate Weld | Step 13 | 201.3 kips | N/A | |
Beam Web to End Plate Weld | Step 13 | 137.5 kips | N/A | |
Column Flange for Flexural Yielding | Step 14 | 0.79 “ | 0.79 “ | 0 |
Column Local Web Yielding | Step 16 | 289.6 kips | 289 kips | 0.2 % (3) |
Column Web Buckling | Step 17 | 330.7 kips | 330 kips | 0 |
Column Web Crippling | Step 18 | 268.2 kips | 275 kips | 2.5% (3) |
Column bolt bearing | Step 13 | 402.5 kips | 404 kips | 0.4% |
- An calculation may not be correct in AISC Design Guide 4 Example 4EB. It could be 5.906, not 6.13 in^2.
- CET.Calculators has more accurate result.
- “N” in local web yielding and web crippling calculation is not consistent in 4E Example B.
Report #
Users can update the contents in this file, which has markdown format. Then the file can be opened in a markdown editor (Typora is preferred). In order to copy the equations, users could change display mode from “Standard” to “Markdown“. Also, in order to show the column calculation, users need to change the “Check member” in “Member” tab from “Beam” to “Column”.
By using Typora, Users can export to PDF format and the final PDF report is like this.
Conclusion #
The Connection Calculator in CET.Calculators can design a 4-bolted unstiffened extended moment end plate connection. Also, users can use this calculator to create professional design report.